High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions
Includes: Basic UPS signaling RS-232 cable, CD with software, Rack mounting brackets, Rack mounting support rails, USB cable, User manual
Max Configurable Power (Watts)
Efficiency at Full Load
Output Frequency (sync to mains)
Other Output Voltages
Load Crest Factor
Topology
Waveform type
Bypass
Input frequency
Input voltage range for main operations
Efficiency at Full Load
Other Input Voltages
Battery type
Typical recharge time
Battery Charge Power (Watts)
Battery Volt-Amp-Hour Capacity
Interface Port(s)
Control panel
Audible Alarm
Emergency Power Off (EPO)
Main Input Voltage | 230 V |
---|---|
Other Input Voltage | 220 V 240 V |
Main Output Voltage | 230 V |
Other Output Voltage | 220 V 240 V |
Rated power in W | 10000 W |
Rated power in VA | 10000 VA |
Output connector type | Hard wire 3-wire (1P + N + E) 1 |
Number of rack unit | 5U |
Provided equipment | 1 USB cable 1 RS-232 configuration cable 2 rack mounting brackets 2 rack mounting support rails 1 external battery pack 1 battery cable user manual |
Number of power module filled slots | 0 |
---|---|
Number of power module free slots | 0 |
Redundant | No |
Colour | Black (RAL 7010) |
---|---|
Height | 22 cm |
Width | 43.8 cm |
Depth | 61.5 cm |
Net weight | 78 kg |
Mounting location | Front |
Mounting preference | Lower |
Mounting mode | Rack-mounted |
USB compatible | Yes |
Mounting position | Horizontal |
Input voltage limits | 110...300 V 60 % load 176...300 V full load |
---|---|
Number of input connectors | 1 hard wire 3-wire (1P + N + E) |
Network frequency | 40...70 Hz auto sensing |
Maximum configurable power in VA | 10000 VA |
---|---|
Maximum configurable power in W | 10000 W |
Output frequency | 50/60 Hz +/- 3 Hz sync to mains |
Harmonic distortion | 1 % |
UPS type | Double conversion online |
Wave type | Sine wave |
Efficiency | 94 % (full load) |
Additional information | Configurable for 220 : 230 or 240 nominal output voltage |
Bypass type | Internal bypass (automatic and manual) |
Crest factor | 3 : 1 |
Product certifications | CE UKCA EAC TISI |
---|---|
Standards | EN/IEC 62040-1:2019/A11:2021 EN/IEC 62040-2:2006/AC:2006 EN/IEC 62040-2:2018 |
Ambient air temperature for operation | 0…40 °C |
---|---|
Relative humidity | 0…95 % non-condensing |
Operating altitude | 0...3000 m |
Ambient air temperature for storage | -15…60 °C |
Storage Relative Humidity | 0…95 % non-condensing |
Storage altitude | 0…15000 m |
Acoustic level | 58 dBA |
Heat dissipation | 2128 Btu/h |