Capacity VA/Watts: 2000 / 1200
Voltage: 220/230/240Vac
Voltage range: 140~300Vac
Frequency Range 50/60Hz (auto sensing)
AC Voltage Regulation(Batt. Mode): ±10%
Frequency Range (Batt. Mode): 50/60Hz ±1 Hz
Transfer Time Typical: 4-8ms, 13ms Max.
Waveform (Batt. Mode): Simulated Sinewave
Dimensions WxDxH (mm): 380*158*198
Weight (Kgs): 10.5
1 KVA 600w Line Interactive UPS with UK type input power cable, with inbuilt 2pcs of 7Ah battery, LED display & includes CHIPSET WITH UNIVERSAL PORTS,back panel with 4PC
The UPS is equipped with two boosts and one buck AVR to stabilize the wide input voltage range. It is also built-in with DC start function. This function enables the UPS to be started up without an AC power supply.
Features |
Line Interactive UPS with simulated sinewave output |
Excellent microprocessor control guarantees high reliability(Internal self-diagnostic technology) |
Boost and buck AVR for voltage stabilization (wide input range with two boost and one buck control) |
Auto restart while AC is recovering |
Cold start function |
Off-mode charging |
Fast intelligent battery recharge function |
Generator compatible |
Offering LED and LCD panels for selections |
Easy installation and operation with compact size |
Ideally applicable for PC, Workstations, TVs, POS devices etc. |
Optional USB/RS232 communication port and RJ11/RJ45 protection |
Model | GN-UPS-LI-1500VA |
|
GN-UPS-LI-2400VA | GN-UPS-LI-3000VA | |
Capacity VA/Watts | 1500 / 900 | 2000 / 1200 | 2400 / 1440 | 3000 / 1800 | |
INPUT | |||||
Voltage | 220/230/240Vac | ||||
Voltage range | 140~300Vac | ||||
Frequency Range | 50/60Hz (auto sensing) | ||||
OUTPUT | |||||
AC Voltage Regulation (Batt. Mode) | ±10% | ||||
Frequency Range (Batt. Mode) | 50/60Hz ±1 Hz | ||||
Transfer Time | Typical 4-8ms, 13ms Max. | ||||
Waveform (Batt. Mode) | Simulated Sinewave | ||||
BATTERY | |||||
Battery Voltage | 12Vdc | 24Vdc | |||
Battery Type & Number | 12 V / 9Ah x 2 | 12 V / 9Ah x 2 | 12 V /7Ah x 4 | 12 V /9Ah x 4 | |
Max charger current (A) | 6~8 hours recover to 90% capacity | ||||
INDICATORS | |||||
LED Display (LED version) | AC Mode, Battery Mode, Overload, Fault | ||||
LCD Display (LCD version) | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Battery Low | ||||
PROTECTION | |||||
Full Protection | Short circuit, Overload , Overcharge and overdischarge protection | ||||
ALARM | |||||
Battery mode | Sounding every 10 seconds | ||||
Low Battery | Sounding every second | ||||
Overload | Sounding every 0.5 second | ||||
Battery Replacement Alarm | Sounding every 2 seconds | ||||
Fault | Continuously sounding | ||||
MANAGEMENT | |||||
Communication port | USB or RS232(Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC) | ||||
OPERATING ENVIRONMENT | |||||
Humidity | 0-90 % RH @ 0- 40°C (non-condensing) | ||||
Noise Level | Less than 55dB | ||||
PHYSICAL | |||||
Dimensions WxDxH (mm) | 380*158*198 | 436*145*212 | |||
Weight (Kgs) | 10.1 | 10.5 | 20 | 23 | |
STANDARDS | |||||
Safety | I EC/EN62040-1, IE C/EN60950-1 | ||||
EMC | I EC/EN62040-2, I EC61000-4-2,1EC61000-4-3,IEC61000-4-4,1EC61000-4-5,IEC61000-4-6, I EC61000-4-8 |